IEC ya Umeme | 75 | 150 | 275 | 320 | 385 | 440 | |
Voltage ya AC (50/60Hz) | Uo/Un | 60V | 120 V | 230 V | 230 V | 230 V | 400 V |
Kiwango cha juu cha Voltage Inayoendelea ya Uendeshaji (AC) | Uc | 75V | 150 V | 275 V | 320 V | 385 V | 440 V |
Utoaji wa Jina wa Sasa (8/20 μs) | In | 20 kA | 20 kA | 20 kA | 20 kA | 10 kA | 10 kA |
Kiwango cha Juu cha Utoaji wa Sasa (8/20 μs) | Imax | 50 kA | 50 kA | 50 kA | 50 kA | 50 kA | 50 kA |
Utoaji wa Msukumo wa Sasa (10/350 μs) | Iimp | 12.5 kA | 12.5 kA | 12.5 kA | 12.5 kA | 10 kA | 10 kA |
Nishati Maalum | W/R | 39 kJ/Ω | 39 kJ/Ω | 39 kJ/Ω | 39 kJ/Ω | 25 kJ/Ω | 25 kJ/Ω |
Malipo | Q | 6.25 Kama | 6.25 Kama | 6.25 Kama | 6.25 Kama | 5 Kama | 5 Kama |
Kiwango cha Ulinzi wa Voltage | Up | 0.7 kV | 1 kV | 1.5 kV | 1.6 kV | 1.8 kV | 2 kV |
Muda wa Majibu | tA | <25 ns | |||||
Fuse ya Hifadhi Rudufu (kiwango cha juu zaidi) | 315 A / 250 A gG | ||||||
Ukadiriaji wa Sasa wa Mzunguko Mfupi (AC) | lSCCR | 25 kA / 50 kA | |||||
TOV Kuhimili sekunde 5 | UT | 114 V | 180V | 335V | 335V | 335V | 580V |
TOV 120min | UT | 114 V | 230V | 440V | 440V | 440V | 765V |
hali | Kuhimili | Imeshindwa Salama | Imeshindwa Salama | Imeshindwa Salama | Imeshindwa Salama | Imeshindwa Salama | |
Umeme wa UL | |||||||
Kiwango cha juu cha Voltage Inayoendelea ya Uendeshaji (AC) | MCOV | 75 V | 150 V | 275 V | 320 V | 385 V | 440 V |
Ukadiriaji wa Ulinzi wa Voltage | VPR | 300 V | 600 V | 900 V | 1200 V | 1350 V | 1500 V |
Utoaji wa Jina wa Sasa (8/20μs) | In | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA |
Ukadiriaji wa Sasa wa Mzunguko Mfupi (AC) | SCCR | ||||||
100 kA | 200 kA | 150 kA | 150 kA | 150 kA | 200 kA | ||
Mitambo na Mazingira | |||||||
Kiwango cha Joto la Uendeshaji | Ta | -40ºF hadi +158ºF [-40ºC hadi +70ºC] | |||||
Unyevu unaoruhusiwa wa Uendeshaji | RH | 5%...95% | |||||
Shinikizo la anga na urefu | 80k Pa ... 106k Pa / -500 m.....2000 m | ||||||
Torque ya Parafujo ya terminal | Mmax | 39.9 Ibf ·katika [Nm 4.5] | |||||
Sehemu ya Msalaba wa Kondakta (kiwango cha juu zaidi) | 2 AWG (Imara, Iliyokwama) / 4 AWG (Inayonyumbulika) | ||||||
35 mm2 (Imara, Iliyokwama) / 25 mm2 (Inayonyumbulika) | |||||||
Kuweka | |||||||
Reli ya DIN ya mm 35, EN 60715 | |||||||
Kiwango cha Ulinzi | IP 20 (imejengwa ndani) | ||||||
Nyenzo ya Makazi | Thermoplastic: Digrii ya Kuzima UL 94 V-0 | ||||||
Ulinzi wa joto | Ndiyo | ||||||
Hali ya Uendeshaji / Dalili ya Makosa | Kijani sawa / kasoro nyekundu | ||||||
Anwani za Mbali (RC) Uwezo wa Kubadilisha RC Sehemu ya Msalaba ya Kondakta wa RC (upeo) | Hiari AC: 250V / 0.5 A;DC: 250V / 0.1 A;125 V / 0.2 A;75 V / 0.5 A 16 AWG (Imara) / 1.5 mm2 (Imara) |
LY1-B 12.5: Ulinzi wa Upasuaji, andika 1+2 hadi EN 61643-11 yenye onyesho la utendaji wa kuona.Kwa kiolesura cha 0 hadi 2 (LPZ) kwa mujibu wa dhana ya eneo la ulinzi wa umeme kwa IEC 61312-1.
• Uwezo wa kukamata 12.5 kA (10/350 µs) kwa kila nguzo
• Matumizi ya nguvuchini ya 26 mW / pole
• Kiwango cha ulinzi<1.5 kV, inaruhusu ulinzi wa kifaa
• Mstari wa kufuata kuzima kwa sasa 25 kA Ipeak
• lncl.plug kofia za kuweka lebo ya miunganisho
• Pengo la cheche lililozimishwa, lisilozimia
• Inaweza kutumika katika makazi ya kawaida ya wasambazaji
Lenga kutoa suluhu za mong pu kwa miaka 5.