IEC ya Umeme | 75 | 150 | 275 | 320 | 385 | 440 | |
Voltage ya AC (50/60Hz) | Uo/Un | 60 V | 120 V | 230 V | 230 V | 230 V | 400 V |
Kiwango cha juu cha Voltage Inayoendelea ya Uendeshaji (AC) | Uc | 75 V | 150 V | 275V | 320 V | 385 V | 440 V |
Utoaji wa Jina wa Sasa (8/20 μs) | In | 10 kA | 10 kA | 10 kA | 10 kA | 10 kA | 10 kA |
Kiwango cha Juu cha Utoaji wa Sasa (8/20 μs) | Imax | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA |
Kiwango cha Ulinzi wa Voltage | Up | 0.2 kV | 0.6 kV | 1.3 kV | 1.5 kV | 1.5 kV | 1.8 kV |
Muda wa Majibu | tA | <25 ns | |||||
Fuse ya Hifadhi Rudufu (kiwango cha juu zaidi) | 125 A gL / gG | ||||||
Ukadiriaji wa Sasa wa Mzunguko Mfupi (AC) | ISCCR | 10 kA | |||||
TOV Kuhimili sekunde 5 | UT | 90V | 180V | 335V | 335V | 335V | 580V |
TOV 120min | UT | 115V | 230V | 440V | 440V | 440V | 765V |
hali | Kuhimili | Kuhimili | Imeshindwa Salama | Imeshindwa Salama | Imeshindwa Salama | Imeshindwa Salama | |
Mitambo na Mazingira | |||||||
Kiwango cha Joto la Uendeshaji | Ta | -40ºF hadi +158ºF [-40ºC hadi +70ºC] | |||||
Unyevu unaoruhusiwa wa Uendeshaji | RH | 5%...95% | |||||
Shinikizo la anga na urefu | 80k Pa ... 106k Pa / -500 m.....2000 m | ||||||
Torque ya Parafujo ya terminal | Mmax | 39.9 Ibf ·katika [Nm 4.5] | |||||
Sehemu ya Msalaba wa Kondakta (kiwango cha juu zaidi) | 2 AWG (Imara, Iliyokwama) / 4 AWG (Inayonyumbulika) | ||||||
35 mm2 (Imara, Iliyokwama) / 25 mm2 (Inayonyumbulika) | |||||||
Kuweka | Reli ya DIN ya mm 35, EN 60715 | ||||||
Kiwango cha Ulinzi | IP 20 (imejengwa ndani) | ||||||
Nyenzo ya Makazi | Thermoplastic: Digrii ya Kuzima UL 94 V-0 | ||||||
Ulinzi wa joto | Ndiyo | ||||||
Hali ya Uendeshaji / Dalili ya Makosa | Kijani sawa / kasoro nyekundu | ||||||
Anwani za Mbali (RC) RC Kubadilisha Uwezo Sehemu Mtambuka ya Kondakta (upeo wa juu) | HiariAC: 250V / 0.5 A;DC: 250V / 0.1 A;125V / 0.2 A;75V / 0.5 A16 AWG (Imara) / 1.5 mm2(Imara) |
Lenga kutoa suluhu za mong pu kwa miaka 5.